Wavelet Phase Coherence¶
What it computes¶
Given two signals, wavelet phase coherence measures how consistently the phase difference between them is maintained over time, at each frequency — i.e. whether two oscillators are synchronized, and at which frequencies/time intervals. A coherence value near 1 means a stable phase relationship; a value near 0 means the phases drift independently.
This differs from simple correlation: two signals can be strongly phase-coherent at one frequency band while being essentially uncorrelated overall.
The mathematics¶
Phase from the wavelet transform¶
Both signals are first passed through the wavelet transform, giving complex coefficients whose argument is the instantaneous phase at each frequency and time:
Time-averaged coherence¶
The key quantity is the phase difference \(\Delta\phi(f,t) = \phi_1(f,t) - \phi_2(f,t)\). Each time point contributes a unit vector \(e^{i\Delta\phi}\) on the complex plane, and coherence is the length of their average:
This is exactly what wphcoh.m computes. The geometry is worth pausing on, because it
explains the whole measure:
- If \(\Delta\phi\) is constant, every unit vector points the same way, they sum coherently, and \(C \to 1\) — regardless of what the constant phase lag is.
- If \(\Delta\phi\) is uniformly random, the vectors cancel and \(C \to 0\).
So \(C\) measures the consistency of the phase relationship, not its value, and it is entirely independent of the amplitudes \(A_1, A_2\) — only the arguments enter. Two very weak but tightly-locked oscillations score as highly as two strong ones.
The routine also returns the mean phase difference \(\arg\left(\langle e^{i\Delta\phi}\rangle\right)\), which is the lag, and is only meaningful when \(C\) is high.
Coherence is biased upward at short records
With \(N\) effectively-independent samples, even two unrelated signals give \(C \approx 1/\sqrt{N}\) rather than 0, because a random walk of \(N\) unit steps has expected length \(\sqrt{N}\). The bias is worst at low frequencies, where few cycles fit in the record. This is why a raw coherence value means little without surrogate testing.
Time-localized coherence¶
Averaging over the whole record assumes the coupling is stationary. tlphcoh.m instead
averages over a sliding window, giving coherence as a function of both time and
frequency:
Crucially the window is a fixed number of cycles, not a fixed duration — in the code
\(w_f = \texttt{wsize} \cdot f_s / f\), with wsize defaulting to 10. Each frequency
therefore averages over the same number of oscillations, so low- and high-frequency
coherence estimates carry comparable statistical weight and the same upward bias.
Implementation-wise this is a cumulative-sum trick, giving the whole sliding average in
\(O(N)\) rather than \(O(N w)\).
Source files¶
allguis/guis/coherence/Functions/wphcoh.m— the core coherence averaging routine.allguis/guis/coherence/Functions/tlphcoh.m— time-localized phase coherence.allguis/guis/coherence/CoherenceMulti.m— the app module, supporting up to several simultaneous signal pairs.
Key parameters¶
- Window length (
wsize) — how many cycles to average the phase difference over, for time-localized coherence. - Frequency range — inherited from the underlying wavelet transform.
Statistical significance¶
Coherence values are compared against a surrogate distribution (see Surrogate Testing) to determine whether an observed coherence level is significant, rather than arising by chance from two independent oscillators — which, per the bias above, it frequently can.
In the web app¶
The Coherence page runs this on 2–6 signals, computing every pairwise combination, with GPU acceleration where available.
Related pages¶
- Dynamical Bayesian Inference — goes further, estimating the form and direction of the coupling rather than only its consistency.
- Maths Primer → Worked Example for coherence applied to a cardiorespiratory-style signal pair.